Open M-F, 9-5 CST
To connect a solar panel to a battery, wire the panel to a charge controller and the controller to the battery: connect the battery to the controller first, then the panel, with an inline fuse on the positive wire of both circuits. Victron and Renogy both specify battery first, and Renogy's manual warns: "NEVER connect the solar panel array to the controller without a battery." To size the panel, by our math about 300 watts refills a fully drained 12V 100Ah battery in one average day in Indiana.
A 12V solar panel puts out far more voltage than a battery can safely take. The Rich Solar MEGA 100 is labeled 22.8 V open circuit voltage, while Rich Solar's ALPHA 1 LiFePO4 manual says charging voltage should be less than 14.4 V and that "charging beyond this absolute maximum voltage is strictly prohibited." A charge controller sits between the two and charges the battery in stages (bulk, absorption, then float or stop), to the voltage set for your battery type.
Set the battery type before you charge. The Rich Solar BRAVO 40 manual lists AGM (14.4 V plus or minus 0.2 V) as the default setting. For a LiFePO4 battery like the ALPHA 1, choose the LFP preset, which charges to 14.2 V plus or minus 0.2 V.
Victron's white paper on controller types explains the difference:
More detail: MPPT vs PWM Charge Controller and What Size Charge Controller Do I Need?
To disconnect, reverse the order: panel first, then battery, so the controller is never left with solar input and no battery. That follows from Renogy's battery first warning; the manuals we checked do not spell out a disconnect order.
A 12V 100Ah battery holds about 12 x 100 = 1,200 Wh. Divide that by the energy each watt of panel collects per day:
Panel watts = battery Wh / (peak sun hours x 0.86)
Peak sun hours come from NREL's solar resource data for Indianapolis. The 0.86 factor is NREL's PVWatts default of 14% system losses (soiling, wiring, and similar); using it for an off-grid battery is our simplification. It leaves out heat losses, which PVWatts models separately, and charge controller and battery charging losses, so real results can be lower.
| Panel mounting and season (Indianapolis) | Peak sun hours | Watts to refill 1,200 Wh from empty | Watts to refill half (600 Wh) |
|---|---|---|---|
| Tilted at latitude, annual average | 4.6 | About 303 W | About 152 W |
| Tilted at latitude, June | 5.6 | About 249 W | About 125 W |
| Tilted at latitude, December | 2.87 | About 486 W | About 243 W |
| Flat, such as an RV roof, annual average | 4.01 | About 348 W | About 174 W |
Sources: NREL (now the National Laboratory of the Rockies) Solar Resource Data API and PVWatts documentation. Watts are our calculation. A LiFePO4 battery rated 12.8 V, such as the ALPHA 1 at 1,280 Wh, needs about 7% more. Your location will differ, so check NREL's PVWatts for your ZIP code.
| Panel size | Wh per day, annual average | Wh per day, December |
|---|---|---|
| 50 W | About 198 Wh | About 123 Wh |
| 100 W | About 396 Wh | About 247 Wh |
| 200 W | About 791 Wh | About 494 Wh |
| 400 W | About 1,582 Wh | About 987 Wh |
Our calculation: panel watts x peak sun hours x 0.86, for panels tilted at latitude in Indianapolis. Also check charge current with Victron's formula, current = watts / battery voltage: 400 W / 13 V = about 31 A, inside the BRAVO 40's 40 A rating and its 600 W recommended maximum on 12V. For how long a charged battery will run your loads, see How Long Will a 12V Battery Last?
Panel voltage rises in the cold. The BRAVO 40 allows a maximum of 100 V open circuit from the panels at -20°C (-4°F). With the MEGA 200's -0.28% per °C Voc coefficient, by our math each panel reaches about 24.5 V at -20°C: 73.6 V for three in series, but 98.2 V for four, which goes over 100 V below about -27°C (-17°F). Four MEGA 100s reach about 102.7 V at -20°C. Keep it to three of either panel in series on a BRAVO 40. See Series vs Parallel Solar Panels.
| Product | What it includes | Price |
|---|---|---|
| Rich Solar 50 Watt solar kit | 50 W panel, 20A MPPT controller, cables, brackets, 10A inline fuse (no battery) | $199.99 |
| Rich Solar 100W RV 12V kit | 100 W panel (RS-M100), 20A MPPT controller, cables, Z brackets, 10A inline fuse; option with a 12V 100Ah LiFePO4 battery | From $299.99 |
| Rich Solar RS-CK400 | Two 200 W panels, 40A MPPT controller, 12V 100Ah lithium battery, 2,000 W 12V inverter, cables, 15A MC4 inline fuse | $1,679.99 |
| Rich Solar BRAVO 40 | 40A MPPT controller, 12V/24V auto, 100 V max panel input, LFP preset | $159.99 |
| Rich Solar MEGA 100 | 100 W 12V panel | $119.99 |
| Rich Solar MEGA 200 | 200 W 12V panel | $239.99 |
| Rich Solar ALPHA 1 | 12.8V 100Ah (1,280 Wh) self-heating LiFePO4 battery | $499.99 |
Kit contents are from each product page. Before your first charge, read How to Charge a LiFePO4 Battery, and if output seems low, see How to Test a Solar Panel.
Need help matching panels to your battery? Call 1-888-855-7286. Tell us your battery's voltage, amp hours, and chemistry, and we will size the panels, controller, wire, and fuses.
Can I connect a solar panel directly to a battery? Use a charge controller. A 12V panel's open circuit voltage (22.8 V on the MEGA 100) is far above a LiFePO4 battery's limit, such as the ALPHA 1's 14.4 V absolute maximum.
Do you connect the battery or the solar panel first? The battery. Victron and Renogy both say to connect the battery to the controller before the panel.
What size solar panel do I need to charge a 12V battery? For a 12V 100Ah battery, about 300 W refills it from empty in an average Indiana day, or about 150 W if you use half of it, by our math. In December it takes about 486 W, so size up if you need winter charging.
How long does it take a 100 watt solar panel to charge a 12V battery? About 3 average days to refill a fully drained 12V 100Ah battery in Indiana: 1,200 Wh / 396 Wh per day, by our math.
Do I need a fuse between the solar panel and charge controller? Rich Solar strongly recommends an inline fuse on the positive wire of both the solar and battery circuits, sized per your controller and panel manuals.