{"product_id":"tigo-ts4-x-s-800w-monitoring-rapid-shutdown","title":"Tigo TS4-X-S 800W Module Monitoring and Rapid Shutdown | 25A Isc, MC4 | 506 Series","description":"\u003ch2\u003eTigo TS4-X-S Monitors and Protects 800W Solar Modules\u003c\/h2\u003e\n\u003cp\u003eThe Tigo TS4-X-S adds module-level monitoring and rapid shutdown to high-power solar modules up to 800W and 25A Isc. It works with the Tigo Access Point (TAP) and Cloud Connect Advanced (CCA), which are required, and supports Multi-factor Rapid Shutdown when paired with the optional RSS Transmitter.\u003c\/p\u003e\n\u003cp\u003eTigo says module-level monitoring and rapid shutdown significantly cut O\u0026amp;M costs and truck rolls.\u003c\/p\u003e\n\u003ch3\u003eWhy You'll Love The Tigo TS4-X-S\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt for 800W modules.\u003c\/strong\u003e 25A Isc and 800W ratings handle the newest high-current panels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEvery module visible.\u003c\/strong\u003e Spot underperforming panels in the Tigo Energy Intelligence platform.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRapid shutdown done right.\u003c\/strong\u003e UL 1741 PVRSE\/PVRSS and UL 3741 PVHCE listed, with shutdown under 30 seconds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInverter freedom.\u003c\/strong\u003e Compatible with thousands of inverter models from more than 50 brands.\u003c\/p\u003e\n\u003ch3\u003eYour life, with the Tigo TS4-X-S\u003c\/h3\u003e\n\u003cp\u003eYou get the safety your inspector needs and the visibility you want, without paying for optimization you do not need. When something changes on the roof, you see it in the app before it costs you.\u003c\/p\u003e\n\u003ch3\u003eThe Tigo TS4-X-S in a nutshell\u003c\/h3\u003e\n\u003ch4\u003eMonitoring plus safety\u003c\/h4\u003e\n\u003cp\u003eModule-level monitoring and rapid shutdown, without optimization.\u003c\/p\u003e\n\u003ch4\u003eCCA and TAP required\u003c\/h4\u003e\n\u003cp\u003eThe TAP links to each TS4 wirelessly and the CCA connects the system to the Tigo cloud.\u003c\/p\u003e\n\u003ch4\u003eTwo cable lengths\u003c\/h4\u003e\n\u003cp\u003eChoose 0.6\/1.2 m or 1.2\/2.0 m input\/output leads with MC4 connectors.\u003c\/p\u003e\n\u003ch4\u003eSimple mounting\u003c\/h4\u003e\n\u003cp\u003eSnaps onto a standard PV module frame or mounts to racking.\u003c\/p\u003e\n\u003ch3\u003eTigo TS4-X-S specifications\u003c\/h3\u003e\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum current (Imp\/Isc):\u003c\/strong\u003e 20A \/ 25A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput voltage range (Vmp):\u003c\/strong\u003e 12 to 80V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum input voltage:\u003c\/strong\u003e 80V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum system voltage:\u003c\/strong\u003e 1500V UL \/ 1000V IEC (MC4 versions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum output current:\u003c\/strong\u003e 20A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum output power:\u003c\/strong\u003e 800W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum efficiency:\u003c\/strong\u003e 99.6%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended fuse rating:\u003c\/strong\u003e 30A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eRapid shutdown and communications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTS4 conductor:\u003c\/strong\u003e 12 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRapid shutdown time limit:\u003c\/strong\u003e Under 30 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePVRSE-controlled conductor limits:\u003c\/strong\u003e 240VA or less, 8A or less, 30VDC or less\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunications:\u003c\/strong\u003e Wireless (TAP and CCA) and\/or PLC (RSS Transmitter)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironmental and mechanical\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -40 to 185°F (-40 to 85°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum elevation:\u003c\/strong\u003e 9,840 ft (3000 m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor rating:\u003c\/strong\u003e IP68\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 5.4 x 5.5 x 0.9 in (139.7 x 138.4 x 22.9 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.15 lb (520 g)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandards, warranty and part numbers\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFCC, IC, CE-EMC, CE-RED, CISPR 31, CSA 22.2, IEC 62109, UL 1741 PVRSE\/PVRSS, UL 3741 PVHCE\u003c\/li\u003e\n\u003cli\u003e25-year warranty\u003c\/li\u003e\n\u003cli\u003e506-340612-2501 (0.6\/1.2 m) and 506-341220-2501 (1.2\/2.0 m), MC4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLet the experts help you find your perfect Tigo TS4-X-S setup\u003c\/h3\u003e\n\u003cp\u003eWant monitoring and safety on a high-power array? Send us your module count and layout and we will size the TS4-X-S units, CCA and TAPs.\u003c\/p\u003e\n\u003cp\u003eEmail \u003ca href=\"mailto:support@kratopower.com\"\u003esupport@kratopower.com\u003c\/a\u003e or call \u003ca href=\"tel:+18888557286\"\u003e+1 888-855-7286\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eTigo TS4-X-S documents and materials\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0548\/9577\/1782\/files\/Tigo-TS4-X-S-Datasheet.pdf?v=1794005257\" target=\"_blank\"\u003eTigo TS4-X-S Datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0548\/9577\/1782\/files\/Tigo-TS4-X-Quick-Start-Guide.pdf?v=1794005410\" target=\"_blank\"\u003eTigo TS4-X Quick Start Guide (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0548\/9577\/1782\/files\/Tigo-TS4-X-TS4-A-725W-Installation-Manual.pdf?v=1794005411\" target=\"_blank\"\u003eTS4-X and TS4-A (725W) Installation Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety disclaimer:\u003c\/strong\u003e PV arrays produce dangerous DC voltage whenever light is present. Installation should be carried out by a licensed electrician in line with the NEC, local codes and the manufacturer's instructions. You use this product at your own risk. The content on this page is general product information, not professional or medical advice. If you have any doubt, consult a qualified professional.\u003c\/p\u003e","brand":"Tigo","offers":[{"title":"0.6\/1.2 m","offer_id":67905322057862,"sku":"506-340612-2501","price":59.97,"currency_code":"USD","in_stock":true},{"title":"1.2\/2.0 m","offer_id":67905322090630,"sku":"506-341220-2501","price":69.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0548\/9577\/1782\/files\/tigo-ts4-x-s-800w-monitoring-rapid-shutdown.jpg?v=1794005890","url":"https:\/\/kratopower.com\/products\/tigo-ts4-x-s-800w-monitoring-rapid-shutdown","provider":"Krato Power","version":"1.0","type":"link"}