{"title":"Generator Interlock Kits","description":"\u003ch2\u003eGenerator Interlock Kits\u003c\/h2\u003e\n\u003cp\u003eA generator interlock kit is the lowest-cost way to back up your home with a portable generator. It mounts on your breaker panel cover so the main breaker and the generator breaker can never be on at the same time, which lets you power your home's circuits through a power inlet box without backfeeding the utility line.\u003c\/p\u003e\n\u003ch3\u003eFind the kit for your panel\u003c\/h3\u003e\n\u003cp\u003eInterlock kits are panel-specific. Match the kit to your panel brand and amperage, then check the main breaker style, which way it throws, and the spacing between the main and the first breaker against the photos and specs on each product page. We carry GenInterlock kits for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSquare D:\u003c\/strong\u003e QO and Homeline 150\/200 amp, Homeline meter main, and vertical throw main panels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGE:\u003c\/strong\u003e 100 amp and 150\/200 amp panels, horizontal and vertical throw\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEaton Cutler Hammer:\u003c\/strong\u003e CH, BR, and plug-on neutral 150\/200 amp panels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens and Murray:\u003c\/strong\u003e 100 amp and 150\/200 amp panels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens, ITE, and Gould:\u003c\/strong\u003e 150\/200 amp panels with a vertical throw main\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBryant:\u003c\/strong\u003e Type BJ 150\/200 amp panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot sure which one fits? Send us a photo of your panel at 888-855-7286 and we will confirm the fit before you order.\u003c\/p\u003e\n\u003ch3\u003eWhat else you need\u003c\/h3\u003e\n\u003cp\u003eAn interlock kit works with a double-pole generator breaker that matches your panel, a \u003ca href=\"\/collections\/transfer-switch-accessories\"\u003epower inlet box and generator cord\u003c\/a\u003e, and a generator with a 30 or 50 amp outlet. Shop \u003ca href=\"\/collections\/generators\"\u003egenerators\u003c\/a\u003e, or compare an interlock with a \u003ca href=\"\/collections\/transfer-switches\"\u003etransfer switch\u003c\/a\u003e in our guide to \u003ca href=\"\/blogs\/news\/interlock-kit-vs-transfer-switch\"\u003einterlock kits vs transfer switches\u003c\/a\u003e. Installation should be done by a licensed electrician where your local code requires it.\u003c\/p\u003e","products":[{"product_id":"geninterlock-sd-200a-generator-interlock-kit","title":"GenInterlock SD-200A Generator Interlock Kit for Square D QO and Homeline 150\/200 Amp Panels","description":"\u003cp\u003eThe GenInterlock SD-200A is a generator interlock kit for Square D QO and Homeline 150\/200 Amp panels. It mounts on your breaker panel cover so the main breaker and the generator breaker can never be on at the same time. That lets you safely power your home's circuits from a portable generator through a power inlet box, without backfeeding the utility line.\u003c\/p\u003e\u003ch3\u003eFits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThis model fits both QO and Homeline 150 and 200 amp panels with this style main breaker\u003c\/li\u003e\n\u003cli\u003eThe spacing between the bottom of the main and the first breaker on the right is 1 3\/8\"\u003c\/li\u003e\n\u003cli\u003eThis fits indoor and outdoor panels with this spacing\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCheck your panel before you order.\u003c\/strong\u003e Interlock kits are panel-specific. Compare your main breaker style, which way it throws, and the spacing between the main and the first breaker against the photos and specs on this page. Not sure? Call us at 888-855-7286 with a photo of your panel and we will confirm the fit.\u003c\/p\u003e\u003ch3\u003eWhat's in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGenInterlock SD-200A interlock kit\u003c\/li\u003e\n\u003cli\u003eOwner's manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e2-year limited factory warranty\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSD-200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGenInterlock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmp\u003c\/td\u003e\n\u003ctd\u003e150\/200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Breaker\u003c\/td\u003e\n\u003ctd\u003e150 or 200 amp single handle Horizontal throw left (off) to right (on)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Breaker\u003c\/td\u003e\n\u003ctd\u003eTop right side 2 positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWhat else you need\u003c\/h3\u003e\u003cp\u003eA double-pole generator breaker that matches your panel, a power inlet box, and a generator cord sized to your generator's outlet. See our \u003ca href=\"\/collections\/transfer-switch-accessories\"\u003einlet boxes and cords\u003c\/a\u003e. Installation should be done by a licensed electrician where your local code requires it. Deciding between an interlock and a transfer switch? Read \u003ca href=\"\/blogs\/news\/interlock-kit-vs-transfer-switch\"\u003einterlock kit vs transfer switch\u003c\/a\u003e.\u003c\/p\u003e","brand":"GenInterlock","offers":[{"title":"Default Title","offer_id":67677971710086,"sku":"GLK-SD-200A","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0548\/9577\/1782\/files\/GLK-SD-200A_1_1800x1800-2.png?v=1791928156"},{"product_id":"geninterlock-bry-200a-generator-interlock-kit","title":"GenInterlock BRY-200A Generator Interlock Kit for Bryant Type BJ 150\/200 Amp Panels with Horizontal Throw Main","description":"\u003cp\u003eThe GenInterlock BRY-200A is a generator interlock kit for Bryant Type BJ 150\/200 Amp panels with Horizontal Throw Main. It mounts on your breaker panel cover so the main breaker and the generator breaker can never be on at the same time. That lets you safely power your home's circuits from a portable generator through a power inlet box, without backfeeding the utility line.\u003c\/p\u003e\u003ch3\u003eFits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFits Bryant Type BJ main breaker 150-200 Amp panels\u003c\/li\u003e\n\u003cli\u003eGenerator Breaker: Top left side 2 positions below main\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCheck your panel before you order.\u003c\/strong\u003e Interlock kits are panel-specific. Compare your main breaker style, which way it throws, and the spacing between the main and the first breaker against the photos and specs on this page. Not sure? Call us at 888-855-7286 with a photo of your panel and we will confirm the fit.\u003c\/p\u003e\u003ch3\u003eWhat's in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGenInterlock BRY-200A interlock kit\u003c\/li\u003e\n\u003cli\u003eOwner's manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e2-year limited factory warranty\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBRY-200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGenInterlock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmp\u003c\/td\u003e\n\u003ctd\u003e150\/200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Breaker\u003c\/td\u003e\n\u003ctd\u003e150 or 200 amp Horizontal throw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Breaker\u003c\/td\u003e\n\u003ctd\u003eTop Left 2 spaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWhat else you need\u003c\/h3\u003e\u003cp\u003eA double-pole generator breaker that matches your panel, a power inlet box, and a generator cord sized to your generator's outlet. See our \u003ca href=\"\/collections\/transfer-switch-accessories\"\u003einlet boxes and cords\u003c\/a\u003e. Installation should be done by a licensed electrician where your local code requires it. Deciding between an interlock and a transfer switch? Read \u003ca href=\"\/blogs\/news\/interlock-kit-vs-transfer-switch\"\u003einterlock kit vs transfer switch\u003c\/a\u003e.\u003c\/p\u003e","brand":"GenInterlock","offers":[{"title":"Default Title","offer_id":67677972594822,"sku":"GLK-BRY-200A","price":69.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0548\/9577\/1782\/files\/GLK-BRY-200A_1_1800x1800-2.png?v=1791928205"},{"product_id":"geninterlock-sie-p1-generator-interlock-kit","title":"GenInterlock SIE-P1 Generator Interlock Kit for Siemens and Murray 100 Amp Panels","description":"\u003cp\u003eThe GenInterlock SIE-P1 is a generator interlock kit for Siemens and Murray 100 Amp panels. It mounts on your breaker panel cover so the main breaker and the generator breaker can never be on at the same time. That lets you safely power your home's circuits from a portable generator through a power inlet box, without backfeeding the utility line.\u003c\/p\u003e\u003ch3\u003eFits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFits both 7\/8 and 1 1\/4 spacing panels\u003c\/li\u003e\n\u003cli\u003eGenerator Breaker Top Left\u003c\/li\u003e\n\u003cli\u003eThe SIE-P1 replaces the MUR-100A\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCheck your panel before you order.\u003c\/strong\u003e Interlock kits are panel-specific. Compare your main breaker style, which way it throws, and the spacing between the main and the first breaker against the photos and specs on this page. Not sure? Call us at 888-855-7286 with a photo of your panel and we will confirm the fit.\u003c\/p\u003e\u003ch3\u003eWhat's in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGenInterlock SIE-P1 interlock kit\u003c\/li\u003e\n\u003cli\u003eOwner's manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e2-year limited factory warranty\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSIE-P1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGenInterlock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmp\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Breaker\u003c\/td\u003e\n\u003ctd\u003e100 amp single handle Horizontal throw Left (on) Right (off) Spacing 7\/8 to 1-1\/4 between Main and Generator breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Breaker\u003c\/td\u003e\n\u003ctd\u003eTop Left side 2 positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWhat else you need\u003c\/h3\u003e\u003cp\u003eA double-pole generator breaker that matches your panel, a power inlet box, and a generator cord sized to your generator's outlet. See our \u003ca href=\"\/collections\/transfer-switch-accessories\"\u003einlet boxes and cords\u003c\/a\u003e. Installation should be done by a licensed electrician where your local code requires it. Deciding between an interlock and a transfer switch? Read \u003ca href=\"\/blogs\/news\/interlock-kit-vs-transfer-switch\"\u003einterlock kit vs transfer switch\u003c\/a\u003e.\u003c\/p\u003e","brand":"GenInterlock","offers":[{"title":"Default Title","offer_id":67677972627590,"sku":"GLK-SIE-P1","price":69.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0548\/9577\/1782\/files\/GLK-SIE-P1_1_1800x1800-2.png?v=1791928206"},{"product_id":"geninterlock-sd-200sa-generator-interlock-kit","title":"GenInterlock SD-200SA Generator Interlock Kit for Square D Homeline Meter Main 150\/200 Amp Panels","description":"\u003cp\u003eThe GenInterlock SD-200SA is a generator interlock kit for Square D Homeline Meter Main 150\/200 Amp panels. It mounts on your breaker panel cover so the main breaker and the generator breaker can never be on at the same time. That lets you safely power your home's circuits from a portable generator through a power inlet box, without backfeeding the utility line.\u003c\/p\u003e\u003ch3\u003eFits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMain Breaker: 200 amp Horizontal throw left (on) and right (off)\u003c\/li\u003e\n\u003cli\u003eGenerator Breaker: Below main\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCheck your panel before you order.\u003c\/strong\u003e Interlock kits are panel-specific. Compare your main breaker style, which way it throws, and the spacing between the main and the first breaker against the photos and specs on this page. Not sure? Call us at 888-855-7286 with a photo of your panel and we will confirm the fit.\u003c\/p\u003e\u003ch3\u003eWhat's in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGenInterlock SD-200SA interlock kit\u003c\/li\u003e\n\u003cli\u003eOwner's manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e2-year limited factory warranty\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSD-200SA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGenInterlock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmp\u003c\/td\u003e\n\u003ctd\u003e150\/200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Breaker\u003c\/td\u003e\n\u003ctd\u003e200 Amp Horizontal throw 4 Handle Main Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Breaker\u003c\/td\u003e\n\u003ctd\u003eBelow Main\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWhat else you need\u003c\/h3\u003e\u003cp\u003eA double-pole generator breaker that matches your panel, a power inlet box, and a generator cord sized to your generator's outlet. See our \u003ca href=\"\/collections\/transfer-switch-accessories\"\u003einlet boxes and cords\u003c\/a\u003e. Installation should be done by a licensed electrician where your local code requires it. Deciding between an interlock and a transfer switch? Read \u003ca href=\"\/blogs\/news\/interlock-kit-vs-transfer-switch\"\u003einterlock kit vs transfer switch\u003c\/a\u003e.\u003c\/p\u003e","brand":"GenInterlock","offers":[{"title":"Default Title","offer_id":67677972660358,"sku":"GLK-SD-200SA","price":64.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0548\/9577\/1782\/files\/GLK-SD-200SA_1_1800x1800-2.png?v=1791928206"},{"product_id":"geninterlock-ge-100a-generator-interlock-kit","title":"GenInterlock GE-100A Generator Interlock Kit for GE 100 Amp Panels","description":"\u003cp\u003eThe GenInterlock GE-100A is a generator interlock kit for GE 100 Amp panels. It mounts on your breaker panel cover so the main breaker and the generator breaker can never be on at the same time. That lets you safely power your home's circuits from a portable generator through a power inlet box, without backfeeding the utility line.\u003c\/p\u003e\u003ch3\u003eFits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMain Breaker: 100 amp single handle Horizontal throw Right (on) to Left (off)\u003c\/li\u003e\n\u003cli\u003e1-3\/8\" Spacing between main and first row of breakers\u003c\/li\u003e\n\u003cli\u003eGenerator Breaker: Top right side 2 positions\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCheck your panel before you order.\u003c\/strong\u003e Interlock kits are panel-specific. Compare your main breaker style, which way it throws, and the spacing between the main and the first breaker against the photos and specs on this page. Not sure? Call us at 888-855-7286 with a photo of your panel and we will confirm the fit.\u003c\/p\u003e\u003ch3\u003eWhat's in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGenInterlock GE-100A interlock kit\u003c\/li\u003e\n\u003cli\u003eOwner's manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e2-year limited factory warranty\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGE-100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGenInterlock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmp\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Breaker\u003c\/td\u003e\n\u003ctd\u003e100 amp single handle Horizontal throw right (on) left (off) 1 3\/8 spacing between main and first breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Breaker\u003c\/td\u003e\n\u003ctd\u003eTop right side 2 positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWhat else you need\u003c\/h3\u003e\u003cp\u003eA double-pole generator breaker that matches your panel, a power inlet box, and a generator cord sized to your generator's outlet. See our \u003ca href=\"\/collections\/transfer-switch-accessories\"\u003einlet boxes and cords\u003c\/a\u003e. Installation should be done by a licensed electrician where your local code requires it. Deciding between an interlock and a transfer switch? Read \u003ca href=\"\/blogs\/news\/interlock-kit-vs-transfer-switch\"\u003einterlock kit vs transfer switch\u003c\/a\u003e.\u003c\/p\u003e","brand":"GenInterlock","offers":[{"title":"Default Title","offer_id":67677972693126,"sku":"GLK-GE-100A","price":67.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0548\/9577\/1782\/files\/GLK-GE-100A_1_1800x1800-2.png?v=1791928207"},{"product_id":"geninterlock-eat-ch200xa-generator-interlock-kit","title":"GenInterlock EAT-CH200XA Generator Interlock Kit for Older Eaton Cutler Hammer CH 150\/200 Amp Panels with Vertical Throw Main","description":"\u003cp\u003eThe GenInterlock EAT-CH200XA is a generator interlock kit for Older Eaton Cutler Hammer CH 150\/200 Amp panels with Vertical Throw Main. It mounts on your breaker panel cover so the main breaker and the generator breaker can never be on at the same time. That lets you safely power your home's circuits from a portable generator through a power inlet box, without backfeeding the utility line.\u003c\/p\u003e\u003ch3\u003eFits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThis model fits 150 and 200 amp Old CH panels with this style main breaker\u003c\/li\u003e\n\u003cli\u003eSpacing between the main and first breaker is 2-1\/4\"\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCheck your panel before you order.\u003c\/strong\u003e Interlock kits are panel-specific. Compare your main breaker style, which way it throws, and the spacing between the main and the first breaker against the photos and specs on this page. Not sure? Call us at 888-855-7286 with a photo of your panel and we will confirm the fit.\u003c\/p\u003e\u003ch3\u003eWhat's in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGenInterlock EAT-CH200XA interlock kit\u003c\/li\u003e\n\u003cli\u003eOwner's manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e2-year limited factory warranty\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eEAT-CH200XA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGenInterlock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmp\u003c\/td\u003e\n\u003ctd\u003e150\/200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel\u003c\/td\u003e\n\u003ctd\u003eCutler Hammer CH Series 150 \u0026amp; 200 Vertical operated main 2-1\/4 spacing from bottom of main to top left breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Breaker\u003c\/td\u003e\n\u003ctd\u003e150 or 200 amp single handle Vertical throw up (on) to down (off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Breaker\u003c\/td\u003e\n\u003ctd\u003eTop left side 2 positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWhat else you need\u003c\/h3\u003e\u003cp\u003eA double-pole generator breaker that matches your panel, a power inlet box, and a generator cord sized to your generator's outlet. See our \u003ca href=\"\/collections\/transfer-switch-accessories\"\u003einlet boxes and cords\u003c\/a\u003e. Installation should be done by a licensed electrician where your local code requires it. Deciding between an interlock and a transfer switch? Read \u003ca href=\"\/blogs\/news\/interlock-kit-vs-transfer-switch\"\u003einterlock kit vs transfer switch\u003c\/a\u003e.\u003c\/p\u003e","brand":"GenInterlock","offers":[{"title":"Default Title","offer_id":67677973741702,"sku":"GLK-EAT-CH200XA","price":64.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0548\/9577\/1782\/files\/GLK-EAT-CH200XA_1_1800x1800-2.png?v=1791928260"},{"product_id":"geninterlock-ge-200hda-generator-interlock-kit","title":"GenInterlock GE-200HDA Generator Interlock Kit for Newer GE 150\/200 Amp Panels with Vertical Throw Main","description":"\u003cp\u003eThe GenInterlock GE-200HDA is a generator interlock kit for Newer GE 150\/200 Amp panels with Vertical Throw Main. It mounts on your breaker panel cover so the main breaker and the generator breaker can never be on at the same time. That lets you safely power your home's circuits from a portable generator through a power inlet box, without backfeeding the utility line.\u003c\/p\u003e\u003ch3\u003eFits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMain Breaker: 150 or 200 amp single handle Vertical throw up (on) down (off)\u003c\/li\u003e\n\u003cli\u003eGenerator Breaker: Top left side 2 positions\u003c\/li\u003e\n\u003cli\u003eRequires 2-1\/4\" spacing between main and feeder breaker\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCheck your panel before you order.\u003c\/strong\u003e Interlock kits are panel-specific. Compare your main breaker style, which way it throws, and the spacing between the main and the first breaker against the photos and specs on this page. Not sure? Call us at 888-855-7286 with a photo of your panel and we will confirm the fit.\u003c\/p\u003e\u003ch3\u003eWhat's in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGenInterlock GE-200HDA interlock kit\u003c\/li\u003e\n\u003cli\u003eOwner's manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e2-year limited factory warranty\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGE-200HDA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGenInterlock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmp\u003c\/td\u003e\n\u003ctd\u003e150\/200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Breaker\u003c\/td\u003e\n\u003ctd\u003e150 or 200 amp single handle Vertical throw up (on) down (off) Spacing between main and the first breaker is 2 ¼ inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Breaker\u003c\/td\u003e\n\u003ctd\u003eTop left side 2 positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWhat else you need\u003c\/h3\u003e\u003cp\u003eA double-pole generator breaker that matches your panel, a power inlet box, and a generator cord sized to your generator's outlet. See our \u003ca href=\"\/collections\/transfer-switch-accessories\"\u003einlet boxes and cords\u003c\/a\u003e. Installation should be done by a licensed electrician where your local code requires it. Deciding between an interlock and a transfer switch? Read \u003ca href=\"\/blogs\/news\/interlock-kit-vs-transfer-switch\"\u003einterlock kit vs transfer switch\u003c\/a\u003e.\u003c\/p\u003e","brand":"GenInterlock","offers":[{"title":"Default Title","offer_id":67677973774470,"sku":"GLK-GE-200HDA","price":69.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0548\/9577\/1782\/files\/GLK-GE-200HDA_1_1800x1800-2.png?v=1791928261"},{"product_id":"geninterlock-sd-200vl-generator-interlock-kit","title":"GenInterlock SD-200VL Generator Interlock Kit for Square D 150\/200 Amp Panels with Vertical Throw Main (3-1\/4 to 4 in. Spacing)","description":"\u003cp\u003eThe GenInterlock SD-200VL is a generator interlock kit for Square D 150\/200 Amp panels with Vertical Throw Main (3-1\/4 to 4 in. Spacing). It mounts on your breaker panel cover so the main breaker and the generator breaker can never be on at the same time. That lets you safely power your home's circuits from a portable generator through a power inlet box, without backfeeding the utility line.\u003c\/p\u003e\u003ch3\u003eFits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMain Breaker: 200 amp single handle Vertical throw down (off), up (on)\u003c\/li\u003e\n\u003cli\u003eGenerator Breaker: Top right side 2 positions\u003c\/li\u003e\n\u003cli\u003eSpacing between the main and first breaker is 3-1\/4 to 4\"\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCheck your panel before you order.\u003c\/strong\u003e Interlock kits are panel-specific. Compare your main breaker style, which way it throws, and the spacing between the main and the first breaker against the photos and specs on this page. Not sure? Call us at 888-855-7286 with a photo of your panel and we will confirm the fit.\u003c\/p\u003e\u003ch3\u003eWhat's in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGenInterlock SD-200VL interlock kit\u003c\/li\u003e\n\u003cli\u003eOwner's manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e2-year limited factory warranty\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSD-200VL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGenInterlock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmp\u003c\/td\u003e\n\u003ctd\u003e150\/200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Breaker\u003c\/td\u003e\n\u003ctd\u003e150 or 200 amp single handle Vertical throw. Spacing from bottom of main to first breaker 3-1\/4 to 4\" inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Breaker\u003c\/td\u003e\n\u003ctd\u003eTop right side 2 positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWhat else you need\u003c\/h3\u003e\u003cp\u003eA double-pole generator breaker that matches your panel, a power inlet box, and a generator cord sized to your generator's outlet. See our \u003ca href=\"\/collections\/transfer-switch-accessories\"\u003einlet boxes and cords\u003c\/a\u003e. Installation should be done by a licensed electrician where your local code requires it. Deciding between an interlock and a transfer switch? Read \u003ca href=\"\/blogs\/news\/interlock-kit-vs-transfer-switch\"\u003einterlock kit vs transfer switch\u003c\/a\u003e.\u003c\/p\u003e","brand":"GenInterlock","offers":[{"title":"Default Title","offer_id":67677973807238,"sku":"GLK-SD-200VL","price":69.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0548\/9577\/1782\/files\/GLK-SD-200VL_1_1800x1800-2.png?v=1791928262"},{"product_id":"geninterlock-ge-200vl-generator-interlock-kit","title":"GenInterlock GE-200VL Generator Interlock Kit for GE 150\/200 Amp Panels with Vertical Throw Main","description":"\u003cp\u003eThe GenInterlock GE-200VL is a generator interlock kit for GE 150\/200 Amp panels with Vertical Throw Main. It mounts on your breaker panel cover so the main breaker and the generator breaker can never be on at the same time. That lets you safely power your home's circuits from a portable generator through a power inlet box, without backfeeding the utility line.\u003c\/p\u003e\u003ch3\u003eFits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e200 amp single handle Vertical throw down (off), up (on)\u003c\/li\u003e\n\u003cli\u003e2 1\/2\" to 3 1\/2 spacing between Main and first usable breaker\u003c\/li\u003e\n\u003cli\u003eGenerator Breaker: Top left side 2 positions\u003c\/li\u003e\n\u003cli\u003eThis model replaced the GE-200VA and the GE-200XL\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCheck your panel before you order.\u003c\/strong\u003e Interlock kits are panel-specific. Compare your main breaker style, which way it throws, and the spacing between the main and the first breaker against the photos and specs on this page. Not sure? Call us at 888-855-7286 with a photo of your panel and we will confirm the fit.\u003c\/p\u003e\u003ch3\u003eWhat's in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGenInterlock GE-200VL interlock kit\u003c\/li\u003e\n\u003cli\u003eOwner's manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e2-year limited factory warranty\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGE-200VL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGenInterlock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmp\u003c\/td\u003e\n\u003ctd\u003e150\/200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Breaker\u003c\/td\u003e\n\u003ctd\u003e200 amp single handle Vertical throw down (off), up (on) 2-1\/2 to 3-1\/2 inch spacing between Main and first breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Breaker\u003c\/td\u003e\n\u003ctd\u003eTop left side 2 positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWhat else you need\u003c\/h3\u003e\u003cp\u003eA double-pole generator breaker that matches your panel, a power inlet box, and a generator cord sized to your generator's outlet. See our \u003ca href=\"\/collections\/transfer-switch-accessories\"\u003einlet boxes and cords\u003c\/a\u003e. Installation should be done by a licensed electrician where your local code requires it. Deciding between an interlock and a transfer switch? Read \u003ca href=\"\/blogs\/news\/interlock-kit-vs-transfer-switch\"\u003einterlock kit vs transfer switch\u003c\/a\u003e.\u003c\/p\u003e","brand":"GenInterlock","offers":[{"title":"Default Title","offer_id":67677973840006,"sku":"GLK-GE-200VL","price":69.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0548\/9577\/1782\/files\/GLK-GE-200VL_1_1800x1800-2.png?v=1791928263"},{"product_id":"geninterlock-eat-ch200a-generator-interlock-kit","title":"GenInterlock EAT-CH200A Generator Interlock Kit for Eaton Cutler Hammer CH 150\/200 Amp Panels (Pre-2019)","description":"\u003cp\u003eThe GenInterlock EAT-CH200A is a generator interlock kit for Eaton Cutler Hammer CH 150\/200 Amp panels (Pre-2019). It mounts on your breaker panel cover so the main breaker and the generator breaker can never be on at the same time. That lets you safely power your home's circuits from a portable generator through a power inlet box, without backfeeding the utility line.\u003c\/p\u003e\u003ch3\u003eFits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor CH Series panels made PRIOR to 2019\u003c\/li\u003e\n\u003cli\u003eThis model fits 150 and 200 amp CH panels with this style main breaker\u003c\/li\u003e\n\u003cli\u003eThe 1-1\/2\" gap between the bottom of the main breaker and top breaker in the panel.\u003c\/li\u003e\n\u003cli\u003eThis interlock does NOT work with the new CH panel with plug-in neutral\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCheck your panel before you order.\u003c\/strong\u003e Interlock kits are panel-specific. Compare your main breaker style, which way it throws, and the spacing between the main and the first breaker against the photos and specs on this page. Not sure? Call us at 888-855-7286 with a photo of your panel and we will confirm the fit.\u003c\/p\u003e\u003ch3\u003eWhat's in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGenInterlock EAT-CH200A interlock kit\u003c\/li\u003e\n\u003cli\u003eOwner's manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e2-year limited factory warranty\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eEAT-CH200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGenInterlock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmp\u003c\/td\u003e\n\u003ctd\u003e150\/200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Breaker\u003c\/td\u003e\n\u003ctd\u003e150 or 200 amp single handle Horizontal throw left (on) to right (off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Breaker\u003c\/td\u003e\n\u003ctd\u003eTop left side 2 positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWhat else you need\u003c\/h3\u003e\u003cp\u003eA double-pole generator breaker that matches your panel, a power inlet box, and a generator cord sized to your generator's outlet. See our \u003ca href=\"\/collections\/transfer-switch-accessories\"\u003einlet boxes and cords\u003c\/a\u003e. Installation should be done by a licensed electrician where your local code requires it. Deciding between an interlock and a transfer switch? Read \u003ca href=\"\/blogs\/news\/interlock-kit-vs-transfer-switch\"\u003einterlock kit vs transfer switch\u003c\/a\u003e.\u003c\/p\u003e","brand":"GenInterlock","offers":[{"title":"Default Title","offer_id":67677974397062,"sku":"GLK-EAT-CH200A","price":69.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0548\/9577\/1782\/files\/GLK-EAT-CH200A_1_1800x1800-2.png?v=1791928317"},{"product_id":"geninterlock-sie-p2-generator-interlock-kit","title":"GenInterlock SIE-P2 Generator Interlock Kit for Siemens and Murray 150\/200 Amp Panels","description":"\u003cp\u003eThe GenInterlock SIE-P2 is a generator interlock kit for Siemens and Murray 150\/200 Amp panels. It mounts on your breaker panel cover so the main breaker and the generator breaker can never be on at the same time. That lets you safely power your home's circuits from a portable generator through a power inlet box, without backfeeding the utility line.\u003c\/p\u003e\u003ch3\u003eFits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFits both 7\/8 and 1-1\/4 spacing panels\u003c\/li\u003e\n\u003cli\u003eGenerator Breaker top Right\u003c\/li\u003e\n\u003cli\u003eReplaces the MUR-200A\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCheck your panel before you order.\u003c\/strong\u003e Interlock kits are panel-specific. Compare your main breaker style, which way it throws, and the spacing between the main and the first breaker against the photos and specs on this page. Not sure? Call us at 888-855-7286 with a photo of your panel and we will confirm the fit.\u003c\/p\u003e\u003ch3\u003eWhat's in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGenInterlock SIE-P2 interlock kit\u003c\/li\u003e\n\u003cli\u003eOwner's manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e2-year limited factory warranty\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSIE-P2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGenInterlock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmp\u003c\/td\u003e\n\u003ctd\u003e150\/200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Breaker\u003c\/td\u003e\n\u003ctd\u003e150 or 200 amp single handle Horizontal throw Right (on) Left (off) Plug on Neutral and Non Plug on Neutral 7\/8 to 1-1\/4 Spacing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Breaker\u003c\/td\u003e\n\u003ctd\u003eTop right side 2 positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWhat else you need\u003c\/h3\u003e\u003cp\u003eA double-pole generator breaker that matches your panel, a power inlet box, and a generator cord sized to your generator's outlet. See our \u003ca href=\"\/collections\/transfer-switch-accessories\"\u003einlet boxes and cords\u003c\/a\u003e. Installation should be done by a licensed electrician where your local code requires it. Deciding between an interlock and a transfer switch? Read \u003ca href=\"\/blogs\/news\/interlock-kit-vs-transfer-switch\"\u003einterlock kit vs transfer switch\u003c\/a\u003e.\u003c\/p\u003e","brand":"GenInterlock","offers":[{"title":"Default Title","offer_id":67677974429830,"sku":"GLK-SIE-P2","price":69.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0548\/9577\/1782\/files\/GLK-SIE-P2_1_1800x1800-2.png?v=1791928318"},{"product_id":"geninterlock-ite-200a-generator-interlock-kit","title":"GenInterlock ITE-200A Generator Interlock Kit for Siemens, ITE, and Gould 150\/200 Amp Panels with Vertical Throw Main","description":"\u003cp\u003eThe GenInterlock ITE-200A is a generator interlock kit for Siemens, ITE, and Gould 150\/200 Amp panels with Vertical Throw Main. It mounts on your breaker panel cover so the main breaker and the generator breaker can never be on at the same time. That lets you safely power your home's circuits from a portable generator through a power inlet box, without backfeeding the utility line.\u003c\/p\u003e\u003ch3\u003eFits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFits Gould, ITE, or Siemens 150-200 Amp panels\u003c\/li\u003e\n\u003cli\u003eMain Breaker: 150 or 200 amp single handle Vertical throw up (on) down (off)\u003c\/li\u003e\n\u003cli\u003eGenerator Breaker: Top left side 2 positions\u003c\/li\u003e\n\u003cli\u003eSpacing between the main and first breaker is 1 1\/4\"\u003c\/li\u003e\n\u003cli\u003eIf 2 1\/4\" spacing is required, use Model #SIE-V2\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCheck your panel before you order.\u003c\/strong\u003e Interlock kits are panel-specific. Compare your main breaker style, which way it throws, and the spacing between the main and the first breaker against the photos and specs on this page. Not sure? Call us at 888-855-7286 with a photo of your panel and we will confirm the fit.\u003c\/p\u003e\u003ch3\u003eWhat's in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGenInterlock ITE-200A interlock kit\u003c\/li\u003e\n\u003cli\u003eOwner's manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e2-year limited factory warranty\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eITE-200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGenInterlock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmp\u003c\/td\u003e\n\u003ctd\u003e150\/200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Breaker\u003c\/td\u003e\n\u003ctd\u003e150 or 200 amp Vertical throw up (on) down (off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Breaker\u003c\/td\u003e\n\u003ctd\u003eTop left side 2 positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWhat else you need\u003c\/h3\u003e\u003cp\u003eA double-pole generator breaker that matches your panel, a power inlet box, and a generator cord sized to your generator's outlet. See our \u003ca href=\"\/collections\/transfer-switch-accessories\"\u003einlet boxes and cords\u003c\/a\u003e. Installation should be done by a licensed electrician where your local code requires it. Deciding between an interlock and a transfer switch? Read \u003ca href=\"\/blogs\/news\/interlock-kit-vs-transfer-switch\"\u003einterlock kit vs transfer switch\u003c\/a\u003e.\u003c\/p\u003e","brand":"GenInterlock","offers":[{"title":"Default Title","offer_id":67677974462598,"sku":"GLK-ITE-200A","price":69.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0548\/9577\/1782\/files\/GLK-ITE-200A_1_1800x1800-2.png?v=1791928319"},{"product_id":"geninterlock-eat-pn200-generator-interlock-kit","title":"GenInterlock EAT-PN200 Generator Interlock Kit for Eaton Cutler Hammer BR and Plug-On Neutral CH 150\/200 Amp Panels","description":"\u003cp\u003eThe GenInterlock EAT-PN200 is a generator interlock kit for Eaton Cutler Hammer BR and Plug-On Neutral CH 150\/200 Amp panels. It mounts on your breaker panel cover so the main breaker and the generator breaker can never be on at the same time. That lets you safely power your home's circuits from a portable generator through a power inlet box, without backfeeding the utility line.\u003c\/p\u003e\u003ch3\u003eFits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThis model fits 150 and 200 amp BR panels with this style main breaker\u003c\/li\u003e\n\u003cli\u003eThe 1-1\/4\" gap between the bottom of the main breaker and top breaker in the panel.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCheck your panel before you order.\u003c\/strong\u003e Interlock kits are panel-specific. Compare your main breaker style, which way it throws, and the spacing between the main and the first breaker against the photos and specs on this page. Not sure? Call us at 888-855-7286 with a photo of your panel and we will confirm the fit.\u003c\/p\u003e\u003ch3\u003eWhat's in the box\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGenInterlock EAT-PN200 interlock kit\u003c\/li\u003e\n\u003cli\u003eOwner's manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e2-year limited factory warranty\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eEAT-PN200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGenInterlock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmp\u003c\/td\u003e\n\u003ctd\u003e150\/200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel\u003c\/td\u003e\n\u003ctd\u003eCutler Hammer BR Series, BR series with Plug in Neutral and CH series with Plug in Neutral 150 \u0026amp; 200 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Breaker\u003c\/td\u003e\n\u003ctd\u003e150 \u0026amp; 200 amp single handle Horizontal throw left (on) to right (off) 1-1\/4 in - 1-1\/2 spacing between main breaker and branch breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Breaker\u003c\/td\u003e\n\u003ctd\u003eTop right side 2 positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWhat else you need\u003c\/h3\u003e\u003cp\u003eA double-pole generator breaker that matches your panel, a power inlet box, and a generator cord sized to your generator's outlet. See our \u003ca href=\"\/collections\/transfer-switch-accessories\"\u003einlet boxes and cords\u003c\/a\u003e. Installation should be done by a licensed electrician where your local code requires it. Deciding between an interlock and a transfer switch? Read \u003ca href=\"\/blogs\/news\/interlock-kit-vs-transfer-switch\"\u003einterlock kit vs transfer switch\u003c\/a\u003e.\u003c\/p\u003e","brand":"GenInterlock","offers":[{"title":"Default Title","offer_id":67677974495366,"sku":"GLK-EAT-PN200","price":67.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0548\/9577\/1782\/files\/GLK-EAT-PN200_1_cc17d7e6-16ed-4bf6-8b4f-0929adbdfe77_1800x1800-2.png?v=1791928320"}],"url":"https:\/\/kratopower.com\/collections\/interlock-kits.oembed","provider":"Krato Power","version":"1.0","type":"link"}